Optional Operations

Making cross-point settings
Cross-point assign tables can be set not only for main output but also for sub
output.
You can set cross-point assign tables for the following banks.
The table actually used is that for which the control panel delegation button is
lit.
For details, see "Cross-Point Settings (Xpt Assign Menu)" in Chapter 19
(Volume 3).
Enabling DME wipe operations for sub
By factory default, DME wipe operations are inhibited for sub background. To
enable them, in the Engineering Setup >Switcher >Config menu, set [DME
Wipe Sub Enable] to On.
This enables DME wipe operations for sub background.
This setting applies to the whole control panel (all M/E banks and PGM/PST
bank).
Notes
If a DME wipe for sub is recalled in a snapshot or keyframe, the image will not
be handled correctly.
Inhibiting utility 2 bus signal selection
In Multi Program 2 mode, you can inhibit other uses of the utility 2 bus signal
in order to use the signal as the background for sub.
This setting applies to the whole control panel (all M/E banks and PGM/PST
bank).
In the Engineering Setup >Panel >Config >MP2 Main/Sub Assign menu, set
[Util2 Inhibit] to On.
This prevents the key row delegation button [UTIL2] from lighting.
Inhibiting key operations for main or sub keyer
In the Engineering Setup >Panel >Config >Operation Inhibit >M/E Operation
Inhibit menu, you can make settings to inhibit key operations on each of the
main and sub keyers independently.