To Lower The Switch Box On The Indoor Unit - Daikin EAVH16S23DA6V Installer's Reference Manual

Hide thumbs Also See for EAVH16S23DA6V:
Table of Contents

Advertisement

7
|
Unit installation

7.2.6 To lower the switch box on the indoor unit

Installer reference guide
64
"7.2.6 To lower the switch box on the indoor
"7.4.4 To connect the drain hose to the
▪ When you need access to the high voltage switch box
T25
5 If you need access to the high voltage components, remove the high voltage
switch box cover.
During the installation, you will need access to the inside of the indoor unit. To
have easier front access, put the switch box lower on the unit as follows:
Prerequisite: The user interface panel and front panel have been removed.
1 Remove the fixing plate at the top of the unit.
2 Tilt the switch box to the front and lift it out of its hinges.
drain" [
T25
4
unit" [
 64]
4
 69]
EPGA11~16DAV3(7) + EAVH/X16S18+23DA6V(7)+9W(7)
Daikin Altherma 3 H F
4P556070-1A – 2021.09

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents