EPGA11~16DAV3(7) + EAVH/X16S18+23DA6V(7)+9W(7)
Daikin Altherma 3 H F
4P556070-1A – 2021.09
4
See
"Setpoint
mode" [
#
Code
[3.4]
N/A
Heating WD curve
Set weather-dependent heating for the additional zone (if [3.4]=1 or 2):
#
Code
[3.5]
[0-00]
[0-01]
[0-02]
[0-03]
Cooling WD curve
Set weather-dependent cooling for the additional zone (if [3.4]=2):
 124].
Setpoint mode:
Fixed
WD heating, fixed cooling
Weather dependent
Set weather-dependent heating:
T t
[0-01]
[0-00]
[0-03]
T
:
Target
t
(additional zone)
T
: Outdoor temperature
a
[0-03]: Low outdoor ambient temperature. –
40°C~+5°C
[0-02]: High outdoor ambient temperature.
10°C~25°C
[0-01]: Desired leaving water temperature
when the outdoor temperature equals or drops
below
the
[9‑05]°C~[9‑06]°C
Note: This value should be higher than [0‑00]
as for low outdoor temperatures warmer water
is required.
[0-00]: Desired leaving water temperature
when the outdoor temperature equals or rises
above
the
[9‑05]~min(45, [9‑06])°C
Note: This value should be lower than [0‑01] as
for high outdoor temperatures less warm water
is required.
10
Configuration
|
Description
Description
[0-02]
T a
leaving
water
temperature
low
ambient
temperature.
high
ambient
temperature.
Installer reference guide
133