Daikin EAVH16S23DA6V Installer's Reference Manual page 90

Hide thumbs Also See for EAVH16S23DA6V:
Table of Contents

Advertisement

9
|
Electrical installation
Installer reference guide
90
b An excessive strip length may cause electrical shock or leakage
3 Insert the wiring at the back of the unit:
c
b
a
a Power supply cable (high voltage)
b Communication cable (high voltage)
c Cable for bottom plate heater (optional)
4 Inside the unit, route the wiring as follows:
b
a
e
f
a Power supply cable
b Communication cable
c Cable for bottom plate heater (optional)
d Ferrite core
e Tie strap
f Compressor
NOTICE
To guarantee electromagnetic compatibility:
Make sure both power supply and communication cables run parallel to one
another. Use tie straps to hold the cables together.
Make sure the cables are located as far away from the compressor as possible.
The communication cable MUST pass through the ferrite core.
5 Make sure that the cable does NOT come in contact with sharp edges or hot
gas piping.
6 Install the switch box cover.
d
e
EPGA11~16DAV3(7) + EAVH/X16S18+23DA6V(7)+9W(7)
c
e
e
e
Daikin Altherma 3 H F
4P556070-1A – 2021.09

Hide quick links:

Advertisement

Table of Contents
loading