  • Page 1 User reference guide Daikin Altherma 3 H F+W EABH16DF6V EAVH16S18DA6V(G) EABH16DF9W EAVH16SU18DA6V EAVH16S23DA6V(G) EABX16DF6V EAVH16SU23DA6V EABX16DF9W EAVH16S18DA9W(G) EAVH16S23DA9W(G) EAVX16S18DA6V(G) EAVX16S23DA6V(G) EAVX16S18DA9W(G) EAVX16S23DA9W(G)
  • Page 2: Table Of Contents

    Symptom: The water at the tap is too cold........................52 Symptom: Heat pump failure ............................52 Symptom: The system is making gurgling noises after commissioning................. 53 User reference guide EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 3 Table of contents 8 Relocation Overview: Relocation ..............................54 9 Disposal 10 Glossary EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 4: General Safety Precautions

    Indicates a situation that could result in minor or moderate injury. NOTICE Indicates a situation that could result in equipment or property damage. INFORMATION Indicates useful tips or additional information. Symbols used on the unit: EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 5: For The User

    ▪ Do NOT rinse the unit. ▪ Do NOT operate the unit with wet hands. ▪ Do NOT place any objects containing water on the unit. EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 6 Waste batteries must be treated at a specialized treatment facility for reuse. By ensuring waste batteries are disposed of correctly, you will help to prevent potential negative consequences for the environment and human health. EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 7: About This Document

    Format: Digital files on http://www.daikineurope.com/support-and-manuals/ product-information/ Latest revisions of the supplied documentation may be available on the regional Daikin website or via your installer. The original documentation is written in English. All other languages are translations. Breadcrumbs Breadcrumbs (example: [4.3]) help you to locate where you are in the menu structure of the user interface.
  • Page 8 2 Press the left dial to enter the submenu. 3 Turn the left dial and go to Operation range. Operation range 4 Press the left dial to enter the submenu. EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 9: About The System

    Radiators, heat pump convectors, or fan coil units INFORMATION The indoor unit and the domestic hot water tank (if installed) can be separated or integrated depending on the indoor unit type. EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 10: Operation

    Dials and buttons You use the dials and buttons: ▪ To navigate through the screens, menus and settings of the LCD screen ▪ To set values EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 11: Possible Screens: Overview

    : Press the right dial. Confirm your choice and go to the next menu item. 4.2 Possible screens: Overview The most common screens are as follows: EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 12: Home Screen

    Go to the main menu screen. Enable/disable breadcrumbs. Item Description The temperatures are shown in circles. If the circle is grey, the corresponding operation (example: space heating) is currently not active. EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 13 ▪ : Fancoil unit ▪ : Radiator g2 Leaving water temperature setpoint g3 Room thermostat type: ▪ : Daikin user interface used as room thermostat ▪ : External control ▪ Hidden: Leaving water temperature control g4 Measured room temperature Additional...
  • Page 14: Main Menu Screen

    You cannot change the mode on heating only models. Tank Restriction: Only displayed if a domestic hot water tank is present. Set the domestic hot water tank temperature. EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 15: Setpoint Screen

    Go through the list of the submenu. Go to the submenu. Adjust and automatically apply the desired temperature. Item Description Minimum temperature limit Fixed by the unit Restricted by the installer EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 16: Detailed Screen With Values

    Room temperature control a Room temperature control ON b Room temperature control OFF EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 17: To Turn On Or Off

    Water pipe freeze prevention. Even if you turn OFF space heating/cooling operation ([C.2]: Operation > Space heating/cooling), water pipe freeze prevention –if enabled– will remain active. EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 18: Space Heating/Cooling Control

    You have to tell the system which operation mode to use. To determine if a heating/cooling heat pump model is installed 1 Go to [4]: Space heating/cooling. EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 19 ▪ Cooling only: Restricted 4 Confirm the changes. Example: Changeover restrictions When Restriction During cold season. Heating only Example: October, November, December, January, February and March. EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 20: Determining Which Temperature Control You Are Using

    During room temperature control, you can use the room temperature setpoint screen to read out and adjust the desired room temperature. 1 Go to [1]: Room. Room EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 21: To Change The Desired Leaving Water Temperature

    You can use the leaving water temperature setpoint screen to read out and adjust the desired leaving water temperature. 1 Go to [2]: Main zone or [3]: Additional zone. Main zone Additional zone EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 22: Domestic Hot Water Control

    4 hours starting from the scheduled start-up of disinfection. If the booster heater is restricted during disinfection, this function will NOT be successful and the applicable warning AH will be generated. EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 23: Reheat Mode

    In reheat mode the DHW tank continuously heats up to the temperature shown on the home screen (example: 50°C) when the temperature drops below a certain value. 60°C 50°C 40°C 15°C 00:00 07:00 14:00 21:00 DHW tank temperature t Time EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 24: Scheduled Mode

    (example: 45°C). This ensures that a minimum amount of hot water is available at all times. Example: EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 25: To Change The Domestic Hot Water Temperature

    1 Go to [5.1]: Tank > Powerful operation 2 Turn powerful operation Off or On. Usage example: You immediately need more hot water You are in the following situation: EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 26: Advanced Usage

    The Advanced user pin code is 1234. Additional menu items for the user are now visible. Advanced user 1234 User pin code The User pin code is 0000. User 0000 EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 27: Using Quiet Mode

    Then you can do the following: 1 Go to [7.4.1]: User settings > Quiet > Activation. 2 Select Most quiet. Advantage: The outdoor unit runs in its most quiet level. EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 28: Using Holiday Mode

    1 Go to [8]: Information. Possible read-out information In menu… You can read out… [8.1] Energy data Produced energy, consumed electricity, and consumed gas [8.2] Malfunction history Malfunction history EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 29: To Configure Time And Date

    ▪ Schedule only present. ▪ Schedule + reheat [5.4] Reheat The software uses this preset value if setpoint the DHW tank mode is Schedule + reheat. EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 30: Setting The Energy Prices

    2 Select the correct electricity price. 3 Confirm the changes. 4 Repeat this for all three electricity prices. — INFORMATION Price value ranging from 0.00~990 valuta/kWh (with 2 significant values). EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 31 Data Price/kWh Gas price 4.08 Electricity price 12.49 Renewable heat incentive per kWh Calculation of the gas price Gas price=Actual gas price+(Incentive/kWh×0.9) Gas price=4.08+(5×0.9) Gas price=8.58 EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 32: Using And Programming Schedules

    2 Select the name of the current schedule. User defined 1 3 Select Select. Delete Rename Select 4 Select the schedule that you currently want to use. EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 33 Off: When the system is NOT allowed to heat additional zone in heating up the additional zone. mode. ▪ On: When the system is allowed to heat up the additional zone. EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 34 Possible actions: You can use the following system-defined preset values: ▪ Quiet ▪ More quiet ▪ Most quiet "About quiet mode" [  27]. EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 35: Schedule Screen: Example

    5 Program the schedule for Saturday and copy it to Sunday. 6 Give the schedule a name. To go to the schedule 1 Go to [1.1]: Room > Schedule. 2 Set scheduling to Yes. EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 36 Delete Edit Copy 3 Select OK to confirm. To program the schedule for Monday 1 Select Monday. User defined 1 2 Select Edit. Delete Edit Copy EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 37 1 Select Monday. User defined 1 2 Select Copy. Delete Edit Copy Result: Next to the copied day, "C" is displayed. 3 Select Tuesday. User defined 1 EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 38 8:00 21°C 23:00 18°C --:-- 4 Confirm the changes. 5 Select Saturday. 6 Select Copy. 7 Select Sunday. 8 Select Paste. Result: User defined 1 EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 39: Weather-Dependent Curve

    Because it reacts more quickly, it prevents high rises and drops of the indoor temperature and water temperature at tap points. Advantage Weather-dependent operation reduces energy consumption. EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 40: 2-Points Curve

    See "Using weather-dependent curves" [  42]. 4.8.2 2-points curve Define the weather-dependent curve with these two setpoints: ▪ Setpoint (X1, Y2) ▪ Setpoint (X2, Y1) Example EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 41: Slope-Offset Curve

    Examples Weather-dependent curve when slope is selected: Weather-dependent curve when offset is selected: EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 42: Using Weather-Dependent Curves

    Viewing which type is selected is also possible via: ▪ [3.C] Additional zone > WD curve type ▪ [5.E] Tank > WD curve type Restriction: Only available to installers. EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 43 At cold outdoor temperatures … temperatures … Cold ↑ — ↑ — ↓ — ↓ — Cold — ↑ — ↑ Cold Cold ↑ ↑ ↑ ↑ EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 44 At cold outdoor temperatures … temperatures … Cold ↓ ↑ ↓ ↑ — ↓ — ↓ Cold ↑ ↓ ↑ ↓ ↓ ↓ ↓ ↓ "2-points curve" [  40]. EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 45: Menu Structure: Overview User Settings

    (*) Only applicable for reversible models, or heating only models + conversion kit INFORMATION Depending on the selected installer settings and unit type, settings will be visible/ invisible. EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 46: Installer Settings: Tables To Be Filled In By Installer

    Comfort setpoint [5.2] Eco setpoint [5.3] Reheat setpoint [5.4] 4.10.2 Settings menu Setting Fill in… Main zone Thermostat type [2.A] Additional zone (if applicable) Thermostat type [3.A] EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 47 Operation Setting Fill in… Information Dealer information [8.3] EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 48: Energy Saving Tips

    Program to turn ON the domestic hot water pump only during periods of the day when instant hot water is necessary. Example: In the morning and evening. EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 49: Maintenance And Service

    Do NOT use the unit until a service person confirms that the part from which the refrigerant leaked has been repaired. EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 50: To Find The Contact/Helpdesk Number

    Maintenance and service 6.2 To find the contact/helpdesk number 1 Go to [8.3]: Information > Dealer information. EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 51: Troubleshooting

    (decrease) room temperature preset value. See "Using preset values" [  29]. ▪ Adjust room temperature schedule. "Using programming schedules"  [   32] and "Schedule screen: Example" [  35]. EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 52: Symptom: The Water At The Tap Is Too Cold

    When auto emergency is set to Manual and a heat pump failure occurs, the domestic hot water and space heating operation will stop and need to be recovered manually via the user interface. To recover operation manually, go to EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 53: Symptom: The System Is Making Gurgling Noises After Commissioning

    If yes, make sure that the room where you want to purge air is sufficiently ventilated. Reason: Refrigerant might leak into the water circuit, and subsequently into the room when you purge air from the heat emitters or collectors. EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 54 8 Relocation 8.1 Overview: Relocation If you want to relocate parts of your system, contact your installer. You can find the contact/helpdesk number via the user interface. EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 55 Do NOT try to dismantle the system yourself: dismantling of the system, treatment of the refrigerant, oil and other parts MUST comply with applicable legislation. Units MUST be treated at a specialised treatment facility for reuse, recycling and recovery. EABH/X16DF6V+9W + EAVH/X16S(U)18+23DA6V+9W User reference guide Daikin Altherma 3 H F+W 4P556071-1B – 2020.12...
  • Page 56 Optional equipment Equipment made or approved by Daikin that can be combined with the product according to the instructions in the accompanying documentation. Field supply Equipment NOT made by Daikin that can be combined with the product according to the instructions in the accompanying documentation.