Information; Installer Settings - Daikin EAVH16S23DA6V Installer's Reference Manual

Hide thumbs Also See for EAVH16S23DA6V:
Table of Contents

Advertisement

10
|
Configuration

10.5.8 Information

10.5.9 Installer settings

Configuration wizard
Domestic hot water
Installer reference guide
150
Electricity price=12.49+5
Electricity price=17.49
Price
Gas: 4.08 /kWh
Electricity: 12.49 /kWh
Dealer information
The installer can fill in his contact number here.
#
Code
[8.3]
N/A
Possible read-out information
In menu...
[8.1] Energy data
[8.2] Malfunction history
[8.3] Dealer information
[8.4] Sensors
[8.5] Actuators
[8.6] Operation modes
[8.7] About
[8.8] Connection status
After first power ON of the system, the user interface will guide you using the
configuration wizard. This way you can set the most important initial settings. This
way the unit will be able to run properly. Afterwards, more detailed settings can be
done via the menu structure if required.
To restart the configuration wizard, go to Installer
Configuration wizard [9.1].
Domestic hot water
The following setting determines if the system can prepare domestic hot water or
not, and which tank is used. This setting is read only.
Value in breadcrumb
[7.6]=8.6
[7.5.1]=17
Description
Number that users can call in case of problems.
You can read out...
Produced energy, consumed electricity,
and consumed gas
Malfunction history
Contact/helpdesk number
Room, tank or domestic hot water,
outside, and leaving water temperature
(if applicable)
Status/mode of each actuator
Example: Domestic hot water pump
ON/OFF
Current operation mode
Example: Defrost/oil return mode
Version information about the system
Information about the connection
status of the unit, the room thermostat
and the LAN adapter.
EPGA11~16DAV3(7) + EAVH/X16S18+23DA6V(7)+9W(7)
settings >
Daikin Altherma 3 H F
4P556070-1A – 2021.09

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents