Code
(a)
[9.2.1]
[E‑05]
(a)
[E‑06]
(a)
[E‑07]
(a)
Use the menu structure instead of the overview settings. Menu structure setting [9.2.1]
replaces the following 3 overview settings:
• [E-05]: Can the system prepare domestic hot water?
• [E-06]: Is a domestic hot water tank installed in the system?
• [E-07]: What kind of domestic hot water tank is installed?
DHW pump
#
Code
[9.2.2]
[D‑02]
Domestic hot water pump installed for...
Instant hot water
a
c
d
a Indoor unit
b Tank
c Domestic hot water pump
d Heater element
e Non‑return valve
f Shower
g Cold water
h Domestic hot water OUT
i Recirculation connection
DHW pump schedule
Program a schedule for the DHW pump (only for field supplied domestic hot
water pump for secondary return).
Program a domestic hot water pump schedule to determine when to turn on and
off the pump.
Description
Integrated
The backup heater will also be used for
domestic hot water heating.
Description
DHW pump:
0: No DHW pump: NOT installed
1: Instant hot water: Installed for instant
hot water when water is tapped. The user sets
the operation timing of the domestic hot water
pump using the schedule. Control of this pump
is possible with the user interface.
2: Disinfection: Installed for disinfection. It
runs when the disinfection function of the
domestic hot water tank is running. No further
settings are needed.
See also illustrations below.
a
b
10
Configuration
|
Disinfection
b
c
d
e
Installer reference guide