3 Remove the switch box cover.
4×
T25
4 If necessary, remove the front plate. This is, for example,
necessary in the following cases:
▪
"4.2.2 To lower the switch box on the indoor
▪
"4.3.2 To connect the drain hose to the
▪ When you need access to the high voltage switch box
2×
T25
5 If you need access to the high voltage components, remove the
high voltage switch box cover.
EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596818-1D – 2021.10
4.2.2
During the installation, you will need access to the inside of the
indoor unit. To have easier front access, put the switch box lower on
the unit as follows:
Prerequisite: The upper front panel and front panel have been
removed.
1 Remove the fixing plate at the top of the unit.
2 Tilt the switch box to the front and lift it out of its hinges.
unit" [ 4 7]
drain" [ 4 8]
3 Place the switch box lower on the unit. Use the 2 hinges located
4.2.3
1 Close the cover of the switch box.
2 Put the switch box back into place.
4×
T25
To lower the switch box on the indoor unit
2×
T25
1
lower on the unit.
To close the indoor unit
4 Unit installation
Installation manual
7