4 Unit installation
T25
4 If necessary, remove the front plate. This is, for example,
necessary in the following cases:
"4.2.2 To lower the switch box on the indoor
"4.3.2 To connect the drain hose to the
▪ When you need access to the high voltage switch box
T25
5 If you need access to the high voltage components, remove the
high voltage switch box cover.
T25
4.2.2

To lower the switch box on the indoor unit

During the installation, you will need access to the inside of the
indoor unit. To have easier front access, put the switch box lower on
the unit as follows:
Installation manual
6
Prerequisite: The upper front panel and front panel have been
removed.
1 Remove the fixing plate at the top of the unit.
2 Tilt the switch box to the front and lift it out of its hinges.
unit" [ 4  6]
drain" [ 4  7]
3 Place the switch box lower on the unit. Use the 2 hinges located
4.2.3
1 Close the cover of the switch box.
2 Put the switch box back into place.
3 Reinstall the top panel.
4 Reinstall the side panels.
5 Reinstall the front panel.
6 Reinstall the upper front panel.
4.3
4.3.1
1 Lift the indoor unit from the pallet and place it on the floor. Also
2 Connect the drain hose to the drain. See
3 Slide the indoor unit into position.
4 Adjust the height of the leveling feet to compensate for floor
T25
1
lower on the unit.

To close the indoor unit

NOTICE
When closing the indoor unit cover, make sure that the
tightening torque does NOT exceed 4.1 N•m.

Mounting the indoor unit

To install the indoor unit

see
"3.1.2 To handle the indoor
drain" [ 4  7].
drain hose to the
irregularities. The maximum allowed deviation is 1°.
unit" [ 4  4].
"4.3.2 To connect the
EHFH03S18D
Daikin Altherma 3 R F
4P596803-1D – 2022.08