Boss BR-1180 Owner's Manual page 117

Digital recording studio
Hide thumbs Also See for BR-1180:
Table of Contents

Advertisement

fig.R16-07
4. Using [CURSOR] again to select the "IMPORT" icon,
then press [ENTER].
The Waveform Data Import screen appears.
fig.R16-56
* If the WAV files are collected in a folder, then the folder name
and icon (
) is displayed. To show the WAV files within
the folder, move the cursor to the folder name and press
[ENTER].
fig.R16-94
5. To switch the format of the wave file you want to
import, move the cursor to "TYPE," then press
[ENTER].
[ENTER] acts as a toggle, switching the file format
between WAV and AIFF each time it's pressed.
6. Use [CURSOR] to select the waveform data files you
want to import.
At this point, you can hear what the waveform data
sounds like by moving the cursor to "PRVW" and
pressing [ENTER] (WAVE Preview). Press [ENTER]
again to cancel the preview.
7. Move the cursor to "SEL," then press [ENTER].
The screen for specifying the import destination appears.
Using the CD-R/RW to exchange data (BR-1180CD)
fig.R16-08
8. Use [CURSOR] and the TIME/VALUE dial to specify
the import-destination track.
9. Use [CURSOR] to move the cursor to "LOC," then
press [ENTER].
The Waveform Data Import (MEAS) screen appears.
fig.R16-80
At this time, you can select "DISP" and press [ENTER] to
switch between ways to specify the location (measures,
time, markers).
Set the following items.
START (start point):
Specify the starting location of the import-destination
track.
END (end point):
Specify the ending location of the import-destination
track..
* If, after specifying the above parameters in terms of location
you switch to the measure or marker indication, a "+" may
appear if a discrepancy between the indicated position and the
actual position arises. When using measures or markers to
make the specification, you can use the TIME/VALUE dial in
the respective screen to eliminate the discrepancy.
* If you want the import range to be from the beginning of the
waveform data to the end, select the "ALL" icon and press
[ENTER].
10. Move the cursor to "GO," then press [ENTER].
Copying of the waveform data begins.
* To quit copying while the import is still in progress, press
[EXIT]. When the message "Cancel?" appears, press [YES];
the import is cancelled (it may take some time after you press
[EXIT] for the message to appear). Files imported up to the
time the process is cancelled are usable.
When "Complete!" appears, the import is finished.