Returning The Mode Switch To Locked Mode; Powering On The Physical Partition Requiring Maintenance - Fujitsu M10-4 Service Manual

Hide thumbs Also See for M10-4:
Table of Contents

Advertisement

6.6
Returning the Mode Switch to Locked
Mode
Return the mode switch of the operation panel to Locked mode.
1.
For a building block configuration, return the mode switches of the master
chassis and those chassis (BB-ID#00, #01) whose XSCFs are in the standby state
to Locked mode.
For details, see
Remarks - For a building block configuration with a connected crossbar box, return the
mode switches of BB-ID#80 and #81 of the crossbar box to Locked mode.
6.7
Powering On the Physical Partition
Requiring Maintenance
This section describes the procedure for powering on a physical partition requiring
maintenance.
1.
Switch the mode switches of the master chassis and those chassis
(BB-ID#00, #01) whose XSCFs are in the standby state to Locked mode.
Log in to the XSCF shell.
2.
Execute the showstatus command to confirm that the FRU is operating
3.
normally after the completion of maintenance.
Nothing is displayed when it is normal.
XSCF> showstatus
Execute the showhardconf command to check the hardware configuration
4.
and the status of each FRU.
XSCF> showhardconf
If the state of the master chassis requiring maintenance has been switched to
5.
the standby state before maintenance, execute the switchscf command to
switch the chassis to the master XSCF.
XSCF> switchscf -t Standby
"2.3.2 Control function of the operation
panel."
Chapter 6 Restoring the System