Fujitsu M10-4 Service Manual page 158

Hide thumbs Also See for M10-4:
Table of Contents

Advertisement

Table 7-7     Active/cold replacement work procedure (building block configuration only)
Item
Work procedure
1
Opening the rack door
2
Checking the operating condition of the
system and the I/O device usage status
3
Releasing the assignment of a PCIe card
4
Releasing the chassis requiring maintenance
from the partition
5
Releasing the chassis requiring maintenance
from the system
6
Enabling access to the FRU requiring
maintenance
7
Replacing a faulty FRU
8
Restoring the chassis requiring maintenance
9
Incorporating the chassis requiring
maintenance into the system
10
Diagnosing the chassis requiring
maintenance
11
Incorporating the chassis requiring
maintenance into a partition
12
Confirming that there is no problem with
the replacement FRU
13
Closing the rack door
*1 Simultaneous replacement of the CPU memory unit and PSU backplane unit is prohibited. To replace the CPU memory unit and PSU
backplane unit, first replace either of the units and perform the work in "9. Incorporating the chassis requiring maintenance into the
system." Then, return to "5. Releasing the chassis requiring maintenance from the system," and replace the other unit. Lastly, restore the
system.
*2 If a CPU memory unit lower is replaced in the system of the hardware RAID volume in a hardware RAID configuration using internal
disks, you need to reactivate the hardware RAID volume before starting Oracle Solaris. Start Oracle Solaris on the control domain as
described in "11. Incorporating the chassis requiring maintenance into a partition." For details, see "14.2.11 Re-enabling a Hardware
RAID Volume" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 System Operation and Administration Guide.
*3 Normally, the testsb command is executed during replacefru command processing. However, if that is canceled, diagnose the system
board before incorporating the chassis requiring maintenance into the physical partition.
144
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ June 2023
Reference
"5.3 Checking the Operating Condition and Resource
Usage
Status"
"5.4.1 Releasing the assignment of I/O
"5.4.3 Releasing a chassis requiring maintenance from the
physical
partition"
"5.8.1 Releasing of the SPARC M10-4S chassis (possible
only in a system with a building block
"5.9 Accessing a
FRU"
See the removal and installation procedures in the
maintenance procedures for each FRU.
"Chapter 8 Maintaining the PCI Express
"Chapter 9 Maintaining the CPU Memory
(*1)(*2)
"Chapter 10 Maintaining the Internal
"Chapter 11 Maintaining the Fan
"Chapter 12 Maintaining the Power Supply
"Chapter 13 Maintaining the PSU Backplane Unit/
Operation
Panel" (*1)
"Chapter 16 Maintaining the XSCF BB Control
"Chapter 17 Maintaining the XSCF DUAL Control
"6.1 Restoring the
Chassis"
"6.2.1 Incorporation of the SPARC M10-4S chassis (possible
only in a system with a building block
"6.3.1 Diagnosing the system
"6.3.2 Diagnosing the crossbar unit and crossbar
"6.5.1 Incorporating a chassis into a physical
"6.3.3 Checking the FRU status after
devices"
configuration)"
Cards"
Unit/Memory"
Disks"
Units"
Units"
Cables"
Cables"
configuration)"
board" (*3)
cables"
partition"
maintenance"

Advertisement

Table of Contents
loading

This manual is also suitable for:

M10-4sSparc m10-4Sparc m10-4s

Table of Contents