Fujitsu M10-4 Service Manual page 69

Hide thumbs Also See for M10-4:
Table of Contents

Advertisement

Checking the status of a PCI expansion unit
If a PCI expansion unit is connected, execute the ioxadm command from the XSCF
shell to check the status of the PCI expansion unit.
- ioxadm command
Execute the ioxadm command to check the environmental conditions (temperature,
voltage, etc.) or LED indications for the PCI expansion unit.
1.
Log in to the XSCF shell.
2.
Execute the ioxadm command to check the environmental conditions of the
specified PCI expansion unit.
To specify a PCI expansion unit, enter the serial number of the PCI expansion
unit after determining it by executing the ioxadm list command.
The following example shows the environmental conditions for the
PCIBOX#2008 "2008" are the last four digits of the serial number of the PCI
expansion unit.
XSCF> ioxadm env -te PCIBOX#2008
Location
PCIBOX#2008
PCIBOX#2008
PCIBOX#2008/PSU#0
PCIBOX#2008/PSU#1
PCIBOX#2008/FAN#0
PCIBOX#2008/FAN#1
PCIBOX#2008/FAN#2
PCIBOX#2008/IOBT
PCIBOX#2008/IOBT
PCIBOX#2008/IOBT
PCIBOX#2008/IOBT
PCIBOX#2008/IOBT
PCIBOX#2008/IOBT
PCIBOX#2008/IOBT
PCIBOX#2008/IOBT
PCIBOX#2008/IOBT
PCIBOX#2008/IOBT
PCIBOX#2008/IOBT
Checking log information
Execute the showlogs command to check error log information.
Log in to the XSCF shell.
1.
Execute the showlogs command to check the log information.
2.
The log information is listed in the order of date, with the oldest appearing first.
The following example shows that an Alarm occurred in PSU#1 at 12:45:31 on
Oct 20, and the status changed to Warning at 15:45:31 on the same day.
Sensor
AIRFLOW
180.000
P_CONSUMPTION
FAN
3936.000
FAN
3584.000
FAN
3374.000
FAN
3374.000
FAN
3374.000
T_INTAKE
T_PART_NO0
T_PART_NO1
T_PART_NO2
V_12_0V
V_3_3_NO0
V_3_3_NO1
V_3_3_NO2
V_3_3_NO3
V_1_8V
V_0_9V
Chapter 4 Preparation and Precautions for Maintenance
Value Resolution Units
0.000 CHM
68.000
0.000 W
0.000 RPM
0.000 RPM
0.000 RPM
0.000 RPM
0.000 RPM
26.000
0.000 C
31.500
0.000 C
30.750
0.000 C
31.500
0.000 C
12.069
0.000 V
3.293
0.000 V
3.295
0.000 V
3.291
0.000 V
3.300
0.000 V
1.804
0.000 V
0.900
0.000 V
55

Advertisement

Table of Contents
loading

This manual is also suitable for:

M10-4sSparc m10-4Sparc m10-4s

Table of Contents