Figure 7-23     Active/hot removal flow (for a PCIe card)
1. Open rack door
2. Check operating condition of system and
I/O device usage status
3. Release assignment of PCIe card
4. Enable removal of a PCIe card for removal
5. Lower cable support
6. Remove PCIe card for removal
7. Fix cable support
8. Confirm that there is no problem with chassis
after removal
9. Close rack door
Table 7-24     Active/hot removal work procedure (for a PCIe card)
Item
Work procedure
1
Opening the rack door
2
Checking the operating condition of
the system and the I/O device usage
status
3
Releasing the assignment of a PCIe
card
4
Enabling the removal of a PCIe card
for removal
5
Lowering the cable support
6
Removing the PCIe card for removal
7
Fixing the cable support
8
Confirming that there is no problem
with the chassis after the removal
9
Closing the rack door
182
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ June 2023
Removal complete
Reference
"5.3 Checking the Operating Condition and Resource Usage
"5.4.1 Releasing the assignment of I/O
"Enabling the removal of a PCI Express
the removal of an I/O
"5.9.2 Lowering the cable
"8.3 FRU Removal and Installation
"6.1.2 Fixing the cable
"6.3.3 Checking the FRU status after
devices"
card" in
device"
support"
Flow"
support"
maintenance"
Status"