Cabling The Core Side - Nortel Meridian 1 Succession 1000M Installation And Configuration Manual

Large system
Hide thumbs Also See for Meridian 1 Succession 1000M:
Table of Contents

Advertisement

Cabling the Core side

Table 25
Field-installed Core cables (internal)
Cable part
number
NT4N88AA
NT4N88BA
NT4N90BA
NTRC17BA
customer supplied
Note: If there is no connection to a LAN, connect the 2 LAN 1 connectors using the
NTRC17BA crossover cable.
Table 26
Factory installed Core cables (internal) (Part 1 of 2)
Cable part
number
NT4N4405
NT4N29AA
Cabling common equipment in a single group system
2
NT4N48AA System Utility card. The System Utility card is located in
slot c15.
3
NT4N64AA Call Processor PII (CP PII). This card is located in the slot
marked CP.
4
NT4N43CA Multi-Media Disk Unit (MMDU). The MMDU is located
in the extreme right hand slot next to the CP PII card. The MMDU
contains the Hard drive, floppy drive, and CD-ROM drive.
This section describes installation of the Core cables. Table 25 lists
field-installed cables. Table 26 lists factory-installed cables.
Description
COM 1 (DTE/terminal)
COM 2 (DCE/modem)
Ethernet (CP PII card to I/O panel)
Crossover Ethernet cable (Core to Core)
Standard Ethernet cable (I/O Panel to LAN
switch)
Description
Shelf Power: Net backplane to Core backplane
cCNI to 3PE Core/Net shelf cable
Large System
Installation and Configuration
Page 157 of 376
Number required
per system
2
2
2
1
2
Number required
per system
2
4

Advertisement

Table of Contents
loading