Nortel Meridian 1 Succession 1000M Installation And Configuration Manual page 232

Large system
Hide thumbs Also See for Meridian 1 Succession 1000M:
Table of Contents

Advertisement

Page 232 of 376
553-3021-210
Standard 1.00
Cabling lines and trunks
Table 42
NT8D37 IPE Module: NT8D14 Universal Trunk Card pair-terminations
Lead designations
RAN
Paging
mode
mode
0T/0R
0T/0R
CP/MB
A/PG
1T/1R
1T/1R
CP/MB
A/PG
2T/2R
2T/2R
CP/MB
A/PG
3T/3R
3T/3R
CP/MB
A/PG
4T/4R
4T/4R
CP/MB
A/PG
5T/5R
5T/5R
CP/MB
A/PG
6T/6R
6T/6R
CP/MB
A/PG
7T/7R
7T/7R
CP/MB
A/PG
Note 1: Each of the following I/O panel connectors is cabled as shown
above: connectors A, B, C, D, E, F, G, H, K, L, M, N, R, S, T, and U. These
connectors are associated with backplane slots 0 through 15, sequentially.
Note 2: Use LD 14 to select trunk termination impedance (600 ohm or
900 ohm). See the Software Input/Output: Administration (553-3001-311)
for information on LD 14.
October 2003
Other
Pin
modes
numbers
0T/0R
26/1
27/2
1T/1R
28/3
29/4
2T/2R
30/5
31/6
3T/3R
32/7
33/8
4T/4R
34/9
35/10
5T/5R
36/11
37/12
6T/6R
38/13
39/14
7T/7R
40/15
41/16
Pair color
Unit
W-BL/BL-W
W-O/O-W
W-G/G-W
W-BR/BR-W
W-S/S-W
R-BL/BL-R
R-O/O-R
R-G/G-R
R-BR/BR-R
R-S/S-R
BK-BL/BL-BK
BK-O/O-BK
BK-G/G-BK
BK-BR/BK-BR
BK-S/S-BK
Y-BL/BL-Y
0
1
2
3
4
5
6
7

Advertisement