Page 100 of 376

Terminal block requirements

553-3021-210
Standard 1.00
Planning and designating the Main Distribution Frame (MDF)
This chapter describes how to install and connect a Succession 1000 system
using the BIX or Krone Test Jack Frame (UK) cross-connect terminals.
This chapter contains the following procedures:
Procedure 11: "Installing the BIX cross-connect terminal" on
Procedure 12: "Installing the Krone Test Jack Frame (UK)" on
The cross-connect terminal requires enough connecting blocks to terminate
up to four 25-pair cables for each Media Gateway and Media Gateway
Expansion. When Ethernet connections are used instead of traditional
cabling, the Succession Media Card Input/Output Adapter is used:
For the 1.5 Mbit DTI/PRI circuit card NTAK09, use the NTBK04 cable.
For the 2.0 Mbit DTI circuit card NTAK10, 2.0 Mbit PRI circuit card
NTAK79, and 2.0 Mbit PRI circuit card NTBK50, use the NTBK05
cable.
For up to four 25-pair cables from each Media Gateway and Media
Gateway Expansion.
— Each slot that is equipped with a trunk or line circuit card requires a
cable.
— If the NTAK19EC 2-port SDI cable or the NTAK19FB 4-port SDI
cable are not used with the NTAK03 or NTAK02 cards, then you
require a 25-pair cable for each of these cards.
Four conductors for the AUX cable from the Media Gateway.
One 25-pair cable from each QUA6 PFTU.
Wiring from telephones and trunks.
DANGER
Always use caution when installing or modifying
telephone lines. Do not install telephone wiring during a
lightning storm. Never touch uninsulated telephone
wiring, unless the line is disconnected at the network
interface.
October 2003
page
101.
page
104.