Terminal block requirements
553-3021-210
Standard 1.00
Planning and designating the Main Distribution Frame (MDF)
This chapter describes how to install and connect a Succession 1000 system
using the BIX or Krone Test Jack Frame (UK) cross-connect terminals.
This chapter contains the following procedures:
•
Procedure 11: "Installing the BIX cross-connect terminal" on
•
Procedure 12: "Installing the Krone Test Jack Frame (UK)" on
The cross-connect terminal requires enough connecting blocks to terminate
up to four 25-pair cables for each Media Gateway and Media Gateway
Expansion. When Ethernet connections are used instead of traditional
cabling, the Succession Media Card Input/Output Adapter is used:
•
For the 1.5 Mbit DTI/PRI circuit card NTAK09, use the NTBK04 cable.
•
For the 2.0 Mbit DTI circuit card NTAK10, 2.0 Mbit PRI circuit card
NTAK79, and 2.0 Mbit PRI circuit card NTBK50, use the NTBK05
cable.
•
For up to four 25-pair cables from each Media Gateway and Media
Gateway Expansion.
— Each slot that is equipped with a trunk or line circuit card requires a
cable.
— If the NTAK19EC 2-port SDI cable or the NTAK19FB 4-port SDI
cable are not used with the NTAK03 or NTAK02 cards, then you
require a 25-pair cable for each of these cards.
•
Four conductors for the AUX cable from the Media Gateway.
•
One 25-pair cable from each QUA6 PFTU.
•
Wiring from telephones and trunks.
DANGER
Always use caution when installing or modifying
telephone lines. Do not install telephone wiring during a
lightning storm. Never touch uninsulated telephone
wiring, unless the line is disconnected at the network
interface.