Connecting a switch box and terminal to the SDI and CPSI/
COM1 ports
Use Procedure 20 to connect CPSI/COM1 ports to a switch box and a
terminal (see Figure 60 on
Procedure 20
Connecting a switch box and terminal to the SDI and CPSI/COM1 ports
1
Set the terminal to 9600 baud, 7 data, space parity, one stop bit, full
duplex, XON.
2
Connect an NT8D95 cable to the terminal and to the switch box.
3
Connect NT8D95 cables to a matching connector on the switch box.
When using an A0377992 ABCDE box, connect:
— CPU 0 to connector A.
— CPU 1 to connector B.
— The SDI port to connector D (connector C is common).
4
Connect NT8D95 cables from the switch box to J25 on the I/O panel in
the rear of each cPCI Core/Network Module.
5
Connect an NT8D95 cable from the switch box to the I/O panel slot for the
SDI card.
6
To communicate with the system in general, set the switch box to the SDI
port. To communicate directly with a CPSI COM1 port, switch the cable
as needed.
Connecting a system terminal or modem
page 140
End of Procedure
Large System
and Figure 61 on
page
Installation and Configuration
Page 141 of 376
142).