Omron NT31C Reference Manual page 390

Hide thumbs Also See for NT31C:
Table of Contents

Advertisement

Commands/Responses
Response
Format
Function
Example
4-3-17 Character String Input Notify Command
Command
Format
380
s
s
:
Check sum (2 hexadecimal digits)
1,
2
This is always added.
None
• In accordance with operations at the PT, such as numeral setting and copying
of memory tables, notifies the host that a numeric value has been input to the
numeral memory table.
• Since it is not possible to write to numeral memory tables from No.247 to
No253 (areas for clock data display/reading use only), notification of these
tables is not executed.
Command
[ESC]
S
N
1B
53
4E
d3
d4
* *
* *
Input numeral memory table number
Input numeric value data (hexadecimal) : 30000H
Check sum (hexadecimal)
Here, it is ascertained that 30000 has been input to numeral memory table
No.150 (whether this is 30000 in hexadecimal or 30000 in BCD is determined by
the numeral storage type set for the numeral memory table).
Input numeral
00196608
00030000
[ESC]
S
1B
53
dn1
* *
t
to t
:
Input character string memory table number (4 BCD digits)
1
4
0000 to 0499
This is the number of the character string memory table for
which there has been character string input.
d1
, d1
, ..., dn
, dn
:
1
2
1
2
Input character string data (1 to 40 characters)
00 to FF
t1
t2
t3
t4
* *
* *
* *
* *
d5
d6
d7
d8
* *
* *
* *
* *
: No.150
: 05H
BCD
Binary
(Sent from PT to Host)
S
t1
t2
t3
53
* *
* *
* *
s1
s2
dn2
* *
* *
* *
H
Section
d1
d2
* *
* *
s1
s2
[CR]
0D
* *
* *
Numeral memory table No. 150
00030000
00030000
t4
d11
d12
* *
* *
* *
[CR]
0D