Omron NT31C Reference Manual page 39

Hide thumbs Also See for NT31C:
Table of Contents

Advertisement

Communications with the Host
1-4-5 Connecting to other Companies' PCs
Compatible PCs
28
Example of Window Control Area Application
When data is written to the window control area, the PT operates as shown be-
low.
PT
Window
(screen No.34)
Opens
Bottom left coordinate
(20, 139)
When the window display status changes, the change is notified to the window
control area as shown below (Window's Opening/Closing status is notified to the
PT status notify area as well).
PT
Window
Move
(screen No.34)
Installing a system program for multi-venders by using a specific system installer
enables the NT31/NT31C or NT631/NT631C to be connected to the PCs of oth-
er companies in direct connection. This system installer is supplied with the Sup-
port Tool (NT-ZJCAT1-EV4).
The NT31/NT31C and NT631/NT631C can be connected to the following Mitsu-
bishi PCs.
• Mitsubishi A series programmable controller (computer link module)
• Mitsubishi FX series programmable controller
For details on the procedure for connecting to other model PCs, refer to the PC
Connection Manual .
PC
WIndow control area
(local window 2)
0034
0020
0139
PC
WIndow control area
PT status notify area
(local window 2)
0034
0180
0219
Bottom left coordinate
(180, 219)
Section
1-4
Screen number
X coordinate
Y coordinate
Screen No.
X coordinate
Y coordinate