Omron NT31C Reference Manual page 267

Hide thumbs Also See for NT31C:
Table of Contents

Advertisement

Device Monitor Function
Specifying/Changing the Word and Clearing the Display
Data
Name
area
DM
Data Memory Area
CH
IR or CIO Area
TIM
Timer Area
CNT
Counter Area
HR
HR (Holding Relay) Area
AR
AR (Auxiliary Relay) Area
LR
LR (Link Relay) Area
WR
Work Area
EM
EM Area (current bank)
EM0 to
EM Area (bank 0 to bank F)
EMF
1, 2, 3...
Reference:
256
Words Displayable in the Registration Monitor Screen
The following table shows which words can be monitored in the registration
monitor screen.
CS1
C200HX/HG/HE (-Z)
f
f
f
f
f
f
---
f
n
n
f: Can be displayed
The CS1-series PC's Task Flags (TK) and clock pulses (P) cannot be displayed.
Procedures
Use the following procedure to specify the word to monitor, change the word's
PV, or clear a word from the display.
1. Press the data area or address cell in the desired row. The following popup
window will be displayed to input the word address. (This example shows
the NT631/631C.)
If you specify a row in which a word is already displayed, that word's data
area and address will be displayed in the popup window.
S Monitoring will stop in a row while the popup window is being displayed to input
a new word address for that row. Monitoring will continue in the other rows and
any changes in those words will appear on the screen.
S No other operations can be performed while the popup window is being dis-
played on the screen. (The PT can be controlled from the PC if the PT is operat-
ing.)
2. Press the Up and Down Arrow Keys (Y and B) to select the desired data
area. The following table shows the order in which the data areas appear
C200HS, CPM1,
CPM2A, CPM2C,
CQM1, or SRM1
f
f
f
f
f
f
f
---
---
n
---
n
---
: Not applicable n: Installed EM banks can be displayed
Section
2-17
CQM1H
f
f
f
f
f
f
f
f
f
f
f
f
f
f
---
n
n

Advertisement