Omron NT31C Reference Manual page 324

Hide thumbs Also See for NT31C:
Table of Contents

Advertisement

Changing Numeral and Character String Display
PT Status Control (word n + 3)
15
14
13
12
11
10
9
8
0
1, 2, 3...
Reference: The range of numeral/character string memory table numbers which can actually
7
6
5
4
3
2
1
0
0
Operate the PT status control area in the manner shown below to copy data be-
tween memory tables.
1. Write the memory table numbers in the PT status control area as indicated
below in either 4-digit BCD or 4-digit hexadecimal. Which of the BCD and
hexadecimal notations is used is determined by the setting for PT Configu-
ration – Storage Type made at the Support Tool.
• 2nd word from the beginning (word n + 1)
0000 to 1999: Copy source memory table No. (0 to 1999)
• 3rd word from the beginning (word n + 2)
0000 to 1999: Copy destination memory table No. (0 to 1999)
be used depends on the number of numeral memory tables and the character
string tables set in PT Configuration – System setting at the Support Tool.
2. Set bit 2 of the 4th word (word n + 3) from the beginning of the PT status
control area as indicated below to match the type of memory table for which
copying is to be executed.
Memory table type: Bit 2
• Character string memory table: 0 (OFF)
• Numeral memory table:
3. Set 1 (ON) for bit 3 of the 4th word (word n + 3) from the beginning of the PT
status control area.
Data copy is executed between the specified type and specified numbers of
memory tables. If the copy destination table is allocated to a word in the host,
the contents at the word in the host are also changed. Then, the occurrence
of a change in the contents of the memory table is notified to the PT status
notify area.
Bit
Controlled Item
Screen display
15
Processing priority registration (for NT link (1:N))
14
Continuous buzzer
13
Intermittent buzzer (short)
12
Display history initialization
11
Not used
10
Intermittent buzzer (long)
9
Backlight mode
8
Screen printing
7
PT window opening
6
Numeral/character string input
5
PT screen switching
4
Memory table copy execution
3
Memory table copy type
2
Alarm history initialization
1
Not used
0
Bits 2 and 3 are not used when the PT is in NT30/620
compatible mode.
1 (ON)
Section
3-5
1 (ON)
0 (OFF)
Performed
Not performed
Registered
Canceled
Sounded
Stopped
Sounded
Stopped
Performed
Not performed
Always 0
Sounded
Stopped
Lit
Flashing
Performed
Not performed
Disabled
Enabled
Disabled
Enabled
Disabled
Enabled
Performed
Not performed
Numeral
Character string
Performed
Not performed
Always 0
313

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nt31Nt631Nt631c

Table of Contents