EPSON Stylus Pro 10000/10000CF/10600
SERVICE REQ. 00010015: liquid sensor overflow (K)
SERVICE REQ. 00010016: liquid sensor overflow (C)
SERVICE REQ. 00010017: liquid sensor overflow (M)
SERVICE REQ. 00010018: liquid sensor overflow (LC)
SERVICE REQ. 00010019: liquid sensor overflow(LM)
SERVICE REQ. 0001001A: liquid sensor overflow(Y)
Problem
Liquid surface sensor overflow
Explanation
The ink tank is held to the printhead to enable high speed printing, and a sensor is
used to control the amount of ink in the tank. This message appears and printer is
stopped when the ink quantity exceeds the sensor "Full" condition during ink
supply. The following table shows service calls by ink color.
Ink Color
1
Black
2
Cyan
3
Magenta
4
Light Cyan
5
Light Magenta
6
Yellow
Solution
1.
Turn power on/off up to 5 times to check for recovery.
2.
If Step 1 is ineffective, check for I/C valve solenoid being left on. (Refer to
Chapter 5)
3.
Replace the PRINT HEAD
4.
Replace the C362DRV board
Troubleshooting
Thank You For Using TheServiceManualShop.com
Table 3-27.
SERVICE REQ.
00010015
00010016
00010017
00010018
00010019
0001001A
Thank You For Using TheServiceManualShop.com
Service engineer require message
SERVICE REQ. 0001001B: head driver (TG) temperature error
Problem
Head driver (TG) temperature error
Explanation
This message appears and printer is stopped when print head internal thermistor
detects abnormal temperature when internal head temperature abnormally
increases beyond required value during printing.
Solution
1.
Check for recovery by turning power on/off.
2.
Replace printhead if problem persists or recurs within short time.
3.
Replace the C362DRV board
SERVICE REQ. 0001001C: FS origin (Suction fan shutter home position)
error
Problem
Paper suction fan shutter origin error
Explanation
This message appears and printer is stopped when shutter home position is not
detected within required time at power on initialization or at paper suction fan
shutter open/close during print start/completion.
Treatment/Check Points
1.
Is shutter origin sensor normal? (Refer to Chapter 5)
2.
Normalizing shutter motor
1) Confirm operation as per Chapter 5
2) Measure resistance
3.
Replace C362DRV Board. In addition, if shutter motor has failed due to short,
replace the board at the same time.