Table 22-13: acSS7LinkCongestionStateChangeAlarmTrap
Alarm:
Additional Info1
varbind
Condition:
Alarm status:
Corrective Action:
Note :
Alarm:
OID:
Default Severity
Event Type:
Probable Cause:
Alarm Text:
Status Changes:
Condition:
Alarm status:
<text> value:
Additional Info1
varbind
Condition:
Alarm status:
User's Manual
acSS7LinkCongestionStateChangeAlarm
%i - <SLC number>
Otherwise there is NO additional text.
%s - <congestion state>: { "UNCONGESTED", "CONGESTED" }
CONGESTED
Link becomes un-congested - local AND remote.
cleared
Reduce SS7 traffic on that link.
This alarm is raised for any change in the remote or local congestion
status.
Table 22-14: acSS7LinkSetStateChangeAlarm Trap
acSS7LinkSetStateChangeAlarm
1.3.6.1.4.1.5003.9.10.1.21.2.0.23
Major
communicationsAlarm
other
*** SS7 *** Linkset %i on SP %i is %s
Operational state of the SS7 link-set becomes BUSY.
Major
%i - <Link-Set number>
%i - <SP number>
%s - <state name: { "OFFLINE", "BUSY", "INSERVICE"}
BUSY
Operational state of the link-set becomes IN-SERVICE or OFFLINE
cleared
390
MG 3200
Document # LTRT-72704