Alarm:
OID:
Default Severity
Event Type:
Probable Cause:
Alarm Text:
Status Changes:
Condition:
Alarm status:
<text> value:
Condition:
Alarm status:
<text> value:
Condition:
Alarm status:
Corrective Action:
Alarm:
OID:
Default Severity
Event Type:
Probable Cause:
Alarm Text:
Note:
Status Changes:
Condition:
User's Manual
Table 22-8: acgwAdminStateChange Alarm Trap
acgwAdminStateChange
1.3.6.1.4.1.5003.9.10.1.21.2.0.7
Major
processingErrorAlarm
outOfService (71)
Network element admin state change alarm Gateway is <text>
Admin state changed to shutting down
Major
shutting down. No time limit.
Admin state changed to locked
Major
locked
Admin state changed to unlocked
cleared
A network administrator has taken an action to lock the device. No
corrective action is required.
Table 22-9: acOperationalStateChange Alarm Trap
acOperationalStateChange
1.3.6.1.4.1.5003.9.10.1.21.2.0.15
Major
processingErrorAlarm
outOfService (71)
Network element operational state change alarm. Operational state is
disabled.
This alarm is raised if the operational state of the node goes to
disabled. The alarm is cleared when the operational state of the node
goes to enabled.
Operational state changed to disabled