ini File Field Name
EnableMultipleIPs
EnableNTPasOAM
EnableSCTPasControl
EnableUDPPortTranslation
EthernetPhyConfiguration
ExtBootPReqEnable
User's Manual
Table 12-3: Infrastructure Parameters
Description
software or hardware malfunction. If
a LAN failure is detected, the board
performs a self reset (when not in
PCI mode).
0 = Disable; 1 = Enable
Enables the multiple IPs feature.
0 = Disable; 1 = Enable
Sets the location of the Network Time
Protocol (NTP). If this parameter is
set and the machine is functioning in
multiple IPs mode, the NTP is
located on the OAM network. If not,
the NTP is located on the control
network.
Sets the location of the Stream
Control Transmission Protocol
(SCTP). If this parameter is set and
the machine is functioning in multiple
IPs mode, the SCTP is located on
the control network. If not, the SCTP
is located on the OAM network.
Specifies the type of compare
operation performed on the UDP
ports. When set, the compare
operation is performed on the UDP
ports. If this parameter is set,
EnableIpAddrTranslation must also
be set.
0 = Disable; 1 = Enable
Controls the Ethernet connection
mode type. Auto-negotiate falls back
to Half-Duplex mode (HD) when the
opposite port is not in Auto-negotiate
mode. The speed (10 Base-T or 100
Base-TX) in this mode is always
configured correctly.
0 = 10 Base-T half-duplex
1 = 10 Base-T full-duplex
2 = 100 Base-TX half-duplex
3 = 100 Base-TX full-duplex
4 = Auto-negotiate
Enables extended information to be
sent in the BootP request. The
device uses the vendor specific
information in the BootP request to
248
MG 3200
Host/Manual
Valid
Default Value
Range
0
0 or 1
1
0 or 1
1
0 or 1
0
0 or 1
4
0 to 4
0
0 or 1