Nortel Media Gateway 3200 User Manual page 382

Hide thumbs Also See for Media Gateway 3200:
Table of Contents

Advertisement

Alarm:
Condition:
Alarm status:
Corrective Action:
Alarm:
OID:
Default Severity
Event Type:
Probable Cause:
Alarm Text:
Status Changes:
Condition:
Alarm status:
<text> value:
Condition:
Alarm status:
Corrective Action:
Alarm:
OID:
Default Severity
Event Type:
Probable Cause:
User's Manual
Table 22-1: acBoardFatalError Alarm Trap
acBoardFatalError
After fatal error
Status stays critical until reboot. A clear trap is not sent.
Capture the alarm information and the syslog close, if active. Contact your
first-level support group. The support group will likely want to collect
additional data from the device and then perform a reset.
Table 22-2: acBoardConfigurationError Alarm Trap
acBoardConfigurationError
1.3.6.1.4.1.5003.9.10.1.21.2.0.2
critical
equipmentAlarm
underlyingResourceUnavailable (56)
Board Config Error: <text>
A configuration error was detected
critical
A run-time specific string describing the configuration error.
After configuration error
Status stays critical until reboot. A clear trap is not sent.
Inspect the run-time specific string to determine the nature of the
configuration error. Fix the configuration error using the appropriate tool:
web interface, EMS, or ini file. Save the configuration and if necessary
reset the device.
Table 22-3: acBoardTemperatureAlarm Alarm Trap
acBoardTemperatureAlarm
1.3.6.1.4.1.5003.9.10.1.21.2.0.3
critical
equipmentAlarm
temperatureUnacceptable (50)
382
MG 3200
Document # LTRT-72704

Advertisement