Nortel Media Gateway 3200 User Manual page 383

Hide thumbs Also See for Media Gateway 3200:
Table of Contents

Advertisement

H.248 User's Manual
Alarm:
Alarm Text:
Status Changes:
Condition:
Alarm status:
Condition:
Alarm status:
Corrective Action:
Alarm:
OID:
Default Severity
Event Type:
Probable Cause:
Alarm Text:
Status Changes:
Condition:
Alarm status:
Condition:
Alarm status:
Corrective Action:
Alarm:
OID:
Default Severity
Version SN09
Table 22-3: acBoardTemperatureAlarm Alarm Trap
acBoardTemperatureAlarm
Board temperature too high
Temperature is above 60 degrees C (140 degrees F)
critical
After raise, temperature falls below 55 degrees C (131 degrees F)
cleared
Inspect the system. Determine if all fans in the system are properly
operating.
Table 22-4: acBoardEvResettingBoard Alarm Trap
acBoardEvResettingBoard
1.3.6.1.4.1.5003.9.10.1.21.2.0.5
critical
equipmentAlarm
outOfService (71)
User resetting board
When a soft reset is triggered via either web interface or SNMP.
critical
After raise
Status stays critical until reboot. A clear trap is not sent.
A network administrator has taken action to reset the device. No
corrective action is needed.
Table 22-5: acFeatureKeyError Alarm Trap
acFeatureKeyError
1.3.6.1.4.1.5003.9.10.1.21.2.0.6
critical
383
22. Appendix - SNMP Traps