Local Plug-In Transformer Configuration - Nortel Meridian SL-100 Reference Manual

Meridian modular telephones
Hide thumbs Also See for Meridian SL-100:
Table of Contents

Advertisement

4-6 Performance specifications
adapter can provide the additional power needed to operate the telephone
and its options. (See Figure 4-2.)
Figure

Local plug-in transformer configuration

The 110V to –48V transformer (AO367335 or equivalent) must meet the
following specifications:
The 220V to –48V transformer (AO367914 or equivalent) must meet the
following specifications:
555-4001-114 Standard 10.02 November 1999
4-2xxx
Adapter plug
1
Jack adapter
1
CAUTION
Possible equipment damage
Do not plug any equipment (computer, modem, LAN
card) other than the Meridian modular telephone into the
RJ-11 transformer adapter, as damage to equipment may
result.
Input voltage—110 V ac / 60 Hz
No load output voltage—29 V ac maximum
Voltage at rated current—26.7 V ac minimum
Rated load current—700 mA
Input voltage—220 V ac / 50 Hz
No load output voltage—29 V ac maximum
Voltage at rated current—26.7 V ac minimum
2
3
4
5
2
3
4
5
6
1
2
Wall transformer
110V or 220V
6