Process; Approvals Data - Siemens SITRANS L Operating Instructions Manual

Radar transmitters with profibus pa
Hide thumbs Also See for SITRANS L:
Table of Contents

Advertisement

Technical specifications

10.6 Process

10.6
Process
Process temperature
Polypropylene rod
PTFE rod or SS horn
Pressure (vessel)
The maximum temperature is dependent on the process connection, antenna materials,
1)
and vessel pressure. For more detail, or for other configurations, see Maximum process
temperature chart (Page 186) and Process pressure/temperature derating curves (Page 187)
onwards.
10.7

Approvals data

Note
The device nameplate lists the approvals that apply to your device.
General
Radio
Marine
Hazardous
152
1)
40 to +80 °C (40 to +176 °F)
40 to +200 °C (40 to +392 °F)
up to 40 bar, gauge (580 psi, gauge)
CSA
, FM, CE, UKCA, RCM
C
US
Europe (RED), FCC, Industry Canada
Lloyd's Register of Shipping, ABS Type Approval
Intrinsically Safe
Europe
Sira 06ATEX2356X: ATEX II 1 G Ex ia IIC T4 Ga
UK
CSAE 21UKEX2084X: UKEX II 1 G Ex ia IIC T4 Ga
International
IECEx SIR 13.0007X: Ex ia IIC T4 Ga
US/Canada
FM/CSA:
Class I, Div. 1, Groups A, B, C, D
Class II, Div. 1, Groups E, F, G
Class III T4
Brazil
INMETRO: DNV 12.0069 X
Ex ia IIC T4 Ga
China
NEPSI: Ex ia IIC T4 Ga
Non-sparking
Europe
Sira 09ATEX4152X: ATEX II 3 G Ex ec IIC T4 Gc
UK
CSAE 21UKEX4083X: UKEX II 3 G Ex ec IIC T4 Gc
China
NEPSI: Ex nA IIC T4 Gc
Non-incendive
US
FM: Class I, Div. 2, Groups A, B, C, D T5
1)
SITRANS LR200 with PROFIBUS PA
Operating Instructions, 07/2021, A5E32337680-AF