Allocation (3.5.); Event Index (3.5.1.) - Siemens SITRANS L Operating Instructions Manual

Radar transmitters with profibus pa
Hide thumbs Also See for SITRANS L:
Table of Contents

Advertisement

7.4.8

Allocation (3.5.)

7.4.8.1

Event index (3.5.1.)

The numeric component of the Event Code for a Condensed Status event. Use the index
number to identify a particular event in the list below.
Event index
0
2
10
11
12
14
15
28
29
30
31
33
34
35
36
37
38
See General fault codes (Page 143) for the meaning of each event.
1)
For example:
Event Code for Loss of Echo
Event Index
To select a particular event via the handheld programmer:
1. Go to Enable (3.4.1.) and select Yes to enable Condensed Mode.
2. Go to Event Index (3.5.1.) and enter the event index number corresponding to the event.
To select a particular event via SIMATIC PDM:
1. Go to Diagnostics > Condensed Status Setup > Condensed Status Mode and select Yes to
enable Condensed Mode.
2. Go to Diagnostics > Condensed Status.
3. For each event, you can select either the Status or the Diagnosis line, then choose a Status
or Diagnosis option from the associated pull-down menu.
SITRANS LR200 with PROFIBUS PA
Operating Instructions, 07/2021, A5E32337680-AF
Event code
Event description
S0
Loss of Echo
S2
No Tech Power
S10
Level Transducer Block (LTB) Scale
S11
Internal Temperature Sensor
S12
Internal Temperature High
S14
AIFB1 PV Range
S15
AIFB2 PV Range
S28
Memory RAM
S29
Memory EEPROM
S30
Memory EEPROM Flags
S31
Memory Flash
S33
Internal Temperature Calibration
S34
Velocity Calibration
S35
Receiver Init Calibration
S36
Receiver Calibration
S37
Technology Module Calibration
S38
Technology Module Ramp
=
S0
=
0
Parameter assignment
1)
7.4 Diagnostics (3.)
119