Data Refresh Timing; Data Synchronization - YASKAWA 264IF-01 User Manual

Machine controller mp2000 series ethercat module
Table of Contents

Advertisement

5.3.2 Data Refresh Timing

The data refresh timing of the MP2000 Series Machine Controller and EtherCAT transmission lines is shown below.
EtherCAT transmission line
MP2000 Series Machine Controller ↔ 264IF-01 Module
Data is refreshed in the timing of the scan setting of I/O allocation in the detailed definitions window of the
264IF-01 Module.
EtherCAT Transmission Lines ↔ 264IF-01 Module
Data is refreshed in the timing of the EtherCAT communication cycle.
Sandwiching a communications IC, operations between an MP2000 Series Machine Controller and 264IF-01 Module,
and between EtherCAT communication lines and the 264IF-01 Module, are asynchronous.

5.3.3 Data Synchronization

The synchronization of data between an MP2000 Series Machine Controller and EtherCAT transmission lines is guar-
anteed.
264IF-01 Module
Communi-
cation
IC
Refreshed in the
communication cycle.
Fig. 5.3 Cyclic Data Refresh Timing of the 264IF-01 Module
5.3 Process Data Communication (Cyclic Communication)
MP2000CPU Series
Machine Controller
Output
register
Input
register
Refreshed in the scan
timing of the I/O allocation
settings.

5.3.2 Data Refresh Timing

5-7
5

Advertisement

Table of Contents
loading