Status Tab Page - YASKAWA 264IF-01 User Manual

Machine controller mp2000 series ethercat module
Table of Contents

Advertisement

4.2 EtherCAT Detail Definition

4.2.2 Status Tab Page

4.2.2 Status Tab Page

The Status tab page displays the status of the 264IF-01 Module.
On this tab page, setting is not possible.
( 1 ) Details of the Status tab page
The following explains each item displayed on the Status tab page.
EtherCAT-S Communication
1
Displays the status of EtherCAT.
The same information as shown by the NS status LED is shown here. The actual indications are as follows.
Non-INIT, INIT, PRE-OPERATIONAL, SAFE-OPERATIONAL, OPERATIONAL
Data Available Flag
2
Displays the process data communication status after turning the power ON.
Enable: EtherCAT process data is communicated.
Disable: EtherCAT process data is not communicated.
 This is a flag that informs the user whether or not process data communication has started.
It is not a flag that is enabled upon reception of any particular process data from the EtherCAT master device.
To check the reception of any particular process data from the EtherCAT master device, make some provision
in the application, for example providing a data refresh bit in the process data.
Vendor ID
3
Displays Yaskawa's (YaskawaE_JP) vendor ID.
Product Code
4
Displays the product code of the 264IF-01 Module.
Software Version
5
Displays the software version of the 264IF-01 Module.
For Ver 1.04, "1.04" is shown.
4-6