5.3 Process Data Communication (Cyclic Communication)

5.3.1 I/O Mapping

5.3 Process Data Communication (Cyclic Communication)

5.3.1 I/O Mapping

This shows the mapping of the EtherCAT logic process data and the I/O registers of the MP2000 Series Machine Con-
troller.
The EtherCAT logic process data space used by the 264IF-01 Module is decided in advance by configuration at the
master node. The position within the Ethernet packets flowing in the network at which the I/O data of a 264IF-01 Mod-
ule is positioned is automatically managed by the communication IC installed in the 264IF-01 Module. This means
that, with the 264IF-01 Module, data can be refreshed just by setting the I/O size, without any awareness of the map-
ping (addresses of the data) of the logic process data of the master node.
0x00000000
Output data
The EtherCAT logic
process data space
is decided in
configuration of
the master device.
Input data
0xFFFFFFFF
5-6
EtherCAT
process data
Fig. 5.2 Mapping of the EtherCAT Logic Process Data Space
MP2000 Series Machine Controller
I/O registers
264IF-01
Module
Mapping of EtherCAT logic process data is
performed inside the 264IF-01 Module,
and the data of input registers and output
registers is refreshed.
Input register
Only the master
side output data can
be taken into the
controller CPU.
Output register