[E870] RADF open jam
Classification
RADF jam
Check item
RADF
RADF opening/closing sensor
RADF board
Replace parts
RADF opening/closing sensor
RADF board
[E871] Cover open jam in the read ready status
Classification
RADF jam
Check item
RADF
Original jam access cover opening/
closing sensor
RADF board
Replace parts
Original jam access cover opening/
closing sensor
RADF board
[E890] ADF time out jam
Classification
RADF jam
Check item
RADF
© 2011 - 2014 TOSHIBA TEC CORPORATION All rights reserved
RADF has opened during RADF operation.
•
Close the RADF if it is opened.
•
Remove if there is any original before closing it.
•
Sensor check
(Perform the input check: 03: [FAX]/ON/[7]/[D])
•
Connector check
•
Harness check
•
Connector check (CN74)
•
Board check
Perform the 05-3210
Jam caused by opening of the Original jam access cover or
front cover while the RADF is waiting for the scanning start
signal from the equipment.
•
Close the RADF if it is opened.
•
Remove if there is any original before closing it.
•
Sensor check
(Perform the input check: 03: [FAX]/ON/[7]/[C])
•
Connector check
•
Harness check
•
Connector check (CN74)
•
Board check
Perform the 05-3210
ADF time out jam
•
Check if there is any paper in the RADF. Remove it if there
is.