Proce
Check item
dure
3
SLG board
4
Scan motor
Parts to be replaced
Carriage home position sensor
Carriage home position sensor
harness
SLG board
Scan motor
Scan motor harness
[C290] Scanner fuse blowout
Classification
Scanning system related
service call
Proce
Check item
dure
1
Is 24V supplied to the SLG
board?
2
SLG board
3
Supply harness
SLG board
LVPS
Parts to be replaced
SLG board
Fuse
Supply harness
LVPS
© 2011 - 2014 TOSHIBA TEC CORPORATION All rights reserved
Measure
1. Check if the harness of the carriage home position sensor is
connected properly.
2. Check if the mounted parts on the SLG board are damaged
or abnormal.
1. Check if the belt tension is loosened (if the motor screw is
loosened).
2. Check if the wire and the belt come off.
3. Check if the connector (J007/J125) is connected to the
motor properly.
4. Check if the harness of the motor is caught or open
circuited.
Remark
Error content
The scanning system does not operate due to a blowout of the fuse
in the scanning system.
Result Measure
Yes
Supplied.
No
Not supplied.
Check the following because the signal for checking 24V on the
SLG board is abnormal.
1. Check if 3V is input in 35 Pin of the scanner CPU (IC15).
2. Check if the mounted parts on the SLG board are damaged
or abnormal.
1. Check if the supply harness is connected properly to the
connector.
1. Check if 24V and SG on the SLG board are short circuited.
2. Check if the power supply is short circuited by pulling out the
supply harness on the SLG board.
1. Check if the fuse on the LVPS is open circuited.
Remark