Download Print this page

Toshiba e-STUDIO5540C Service Manual page 467

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO5540C:

Advertisement

Sub
05/08
Mode
Element
element
08
Setting
System
Scanner
Mode
08
Setting
System
Network
Direct SMTP
Mode
08
Setting
System
Network
Direct SMTP
Mode
e-STUDIO5540C/6540C/6550C (Ver08)
Sub-
Item
Subitem
Code
code
3805
3810
3811
Default
Acceptable
Details
value
value
Department
3
0-3
Management setting
by Remote Scan
Communication
0
<0-1>
setting
Image encrypting at
0
<0-1>
the Direct SMTP
60
RAM
Contents
SYS Sets the department management with remote scanning
as follows:
0: w/o GUI OFF,w/ GUI OFF
1: w/o GUI ON, w/ GUI OFF
2: w/o GUI OFF, w/ GUI ON
3: w/o GUI ON, w/ GUI ON
w/o GUI:
Remote scanning is operated on SSOP application of
eCOPY Inc.
w/ GUI:
Remote scanning is operated on TTEC-specific GUI.
This setting is only for department management with
remote scanning. When GUI is set ON, a department
code dialog is displayed at the start-up of remote
scanning. This code is valid only when the code 08-
9120 is set "1 (Valid)".
SYS When an Internet Fax is sent, Direct SMTP
communication is set.
0: Disabled
1: Enabled
When "0: Disabled" is set, an Internet Fax is sent using
an SMTP server. When "1: Enabled" is set, direct
SMTP communication is enabled and an Internet Fax is
sent to MFPs
If "1: Enabled" is set in 08-3810, set "1: Enabled" in 08-
3812 as well.
SYS When Direct SMTP communication is performed, an
attached image is encrypted.
0: Disabled
1: Enabled
Proce
Servic
dure
e UI
1
1
Yes
1
Yes

Advertisement