Check item
Needle electrode cleaner drive
motors (M23 - M26)
Needle electrode cleaner drive
section
EPU board
LGC board
Replace parts
Needle electrode cleaner detection
sensor
Needle electrode cleaner drive motor
EPU board
LGC board
[C370] Transfer belt abnormality
Classification
Copy process related service call
Check item
Transfer belt unit
Transfer belt cam motor (M14)
Transfer belt contact/release
detection sensor (S46)
LGC board
Replace parts
Transfer belt contact/release
detection sensor (S46)
Transfer belt cam motor (M14)
LGC board
[C380] Auto-toner sensor (K) abnormality (upper limit)
[C381] Auto-toner sensor (K) abnormality (lower limit)
[C382] Auto-toner sensor (K) connection error
© 2011 - 2014 TOSHIBA TEC CORPORATION All rights reserved
•
Motor check
(Perform the output check: K: 03-207, C: 03-206, M: 03-
205, Y: 03-204)
•
Connector check
•
Harness check
•
Check if the needle electrode cleaner drive section rotates
smoothly, and if it does not, clean or replace it.
•
Connector check (CN550, CN551, CN553, CN554,
CN555, CN556)
•
Board check
•
Connector check (CN308, CN310)
•
Harness check
•
Board check
•
Connector check
•
Unit check
•
Motor check
(Perform the output check: 03-237)
•
Connector check
•
Harness check
•
Sensor check
(Perform the input check: 03-[ALL]OFF/[5]/[H])
•
Connector check
•
Harness check
•
Connector check (CN311)
•
Board check
e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
8 - 175
Measures
Remarks
Error item
Measures
Remarks
ERROR CODE and TROUBLESHOOTING