Troubleshooting
Proportioning

Proportioning System

Proportioning
System
System
Before performing any troubleshooting
procedures:
1. Follow
Pressure Relief Procedure, page
PROBLEM
PROBLEM
PROBLEM
Proportioning pump does not
hold pressure when stalled.
Material Imbalance. See
Pressure/Material Imbalance,
page
41.
40
2. Turn the main power switch OFF.
3. Allow equipment to cool.
Problems:
Problems:
Problems:
Try the recommended solutions in the order
given for each problem, to avoid unnecessary
repairs. Also, determine that all circuit breakers,
switches, and controls are properly set and
wiring is correct before assuming there is a
49.
problem.
CAUSE
CAUSE
CAUSE
Pump piston or intake valve
leaking.
Restriction at the gun.
Inadequate flow from pump;
cavitation.
Pressure relief/circulation valve
leaking back to supply.
SOLUTION
SOLUTION
SOLUTION
1. Observe gauges to
determine which pump
is losing pressure.
2. Determine in which direction
the pump has stalled by
observing which directional
icon is displayed on the ADM
Home screen. See Table 1.
3. Repair the valve. See pump
manual.
Clean the gun; see your separate
gun manual.
Increase fluid supply to
proportioning pump:
• Use 2:1 supply pump
• Use minimum 3/4 in. (19 mm)
ID supply hose, as short as
practical
Fluid is too thick. Consult
your material supplier for the
recommended fluid temperature
to maintain a viscosity of 250 to
1500 centipoise.
Clean inlet strainer screen.
Worn pump inlet valve ball/seat
or gasket. Replace pump.
Remove return line and
determine if flow is present
while in SPRAY mode.
334946J