Graco Reactor 2 Repair Parts page 31

Hydraulic proportioning systems
Hide thumbs Also See for Reactor 2:
Table of Contents

Advertisement

Error
Location
Error
Error
Location
Location
T4DA
Heater A
T4DB
Heater B
T4DH
Hose
334946J
Type
Description
Type
Type
Description
Description
High Temperature
A
High Temperature
B
High Temperature
Hose
Cause
Cause
Cause
Solution
Solution
Solution
Module fan not
If a TCM fan error
operating
(WMI0) has occurred,
fan inside the module
is not working properly.
Check TCM fan for debris
and clear with forced air
if necessary.
Bad RTD or bad
Swap A and B heater
RTD placement
output cables and RTD
against heater
cables and see if issue
follows. If so, replace
RTD.
Flow too high
Use a smaller mix
for temperature
chamber that is rated
setpoint, causing
for the unit in use.
temperature
overshoots
when gun is
de-triggered
Bad RTD or bad
Swap A and B heater
RTD placement
output cables and RTD
against heater
cables and see if issue
follows. If so, replace
RTD.
Flow too high
Use a smaller mix
for temperature
chamber that is rated
setpoint, causing
for the unit in use.
temperature
overshoots
when gun is
de-triggered
Hose portion
Shade exposed hose from
exposed to an
hot sun or expose FTS to
excessive heat
same environment when
source, like hot
at rest. Uncoil entire
sun or coiled
hose before heating to
hose, can pass
avoid self-heating.
fluid more than
27°F (15°C) over
hose temperature
setting to the FTS
Setting the A
Increase hose setpoint
or B setpoint
so it is closer to A and B
much higher than
setpoints.
hose setpoint
can cause fluid
more than 27°F
(15°C) over hose
temperature
setting to reach
the FTS.