Proportioner Assembly Parts - Graco Reactor 2 Repair Parts

Hydraulic proportioning systems
Hide thumbs Also See for Reactor 2:
Table of Contents

Advertisement

Proportioner Assembly
Assembly Parts
Proportioner
Proportioner
Assembly
Torque to 200 in-lb (22.6 N●m).
1
Pin (213) to be clocked horizontal as shown.
3.
Apply sst pipe sealant to all non-swiveling
pipe threads.
Remove cover from directional valve (207)
and attach solenoid harness wires (225). See
Electrical Schematics, page
334946J
Parts
Parts
105.
Fully seat pin (213) with a hammer and
punch.
Thread in proximity switch (211) all the way
until it contacts the clocking plate, then back
off a 1/4–1/2 turn.
Apply grease to o-rings (204, 216) before
assembly.