Graco Reactor 2 Repair Parts page 23

Hydraulic proportioning systems
Hide thumbs Also See for Reactor 2:
Table of Contents

Advertisement

Error
Location
Error
Error
Location
Location
P1FA
HCM
P1FB
HCM
P2FA
HCM
P2FB
HCM
334946J
Type
Description
Type
Type
Description
Description
Low Inlet Pressure
A
Low Inlet Pressure
B
Low Inlet Pressure
A
Low Inlet Pressure
B
Cause
Cause
Cause
Solution
Solution
Solution
Fluid leaking
Check if heater and
from heater inlet
PRESSURE RELIEF/SPRAY
rupture disk
valve are plugged. Clear.
Replace rupture disk. Do
not replace with a pipe
plug.
Feed system
Check feed pump and
defective
hoses for blockage.
Check that feed pumps
have correct air pressure.
Inlet pressure
Ensure that inlet pressure
lower than
to the pump is sufficient.
defined value
Value defined too
Ensure that the
high
low pressure alarm
level defined on the
System Setup screen is
acceptable.
Inlet pressure
Ensure that inlet pressure
lower than
to the pump is sufficient.
defined value
Value defined too
Ensure that the
high
low pressure alarm
level defined on the
System Setup screen is
acceptable.
Inlet pressure
Ensure that inlet pressure
lower than
to the pump is sufficient.
defined value
Value defined too
Ensure that the
high
low pressure alarm
level defined on the
System Setup screen is
acceptable.
Inlet pressure
Ensure that inlet pressure
lower than
to the pump is sufficient.
defined value
Ensure that the
Value defined too
low pressure alarm
high
level defined on the
System Setup screen is
acceptable.
Troubleshooting
23