Clean Flow Meter - Graco Reactor 2 Repair Parts

Hydraulic proportioning systems
Hide thumbs Also See for Reactor 2:
Table of Contents

Advertisement

Repair
Clean Flow
Flow Meter
Meter
Clean
Clean
Flow
Meter
1. Perform
Shutdown, page
2. Perform
Pressure Relief Procedure, page
3. Disconnect the flow meter cable.
4. Disconnect the heated hose from the flow
meter. Remove the flow meter.
5. Remove four screws (VS) and remove the top
cover (PL).
6. Remove eight screws (MS) and remove the
metal cap (SD).
7. Remove gears (GS) from the housing (HG).
8. Clean the gears and the fluid section of the
housing with compatible solvent.
56
50.
49.
9. Reinstall the gears.
a. Place the gear with the magnets (MG) on
the left pin of the housing.
NOTE:
NOTE: The gear with the magnets (MG)
NOTE:
must be installed on the left side or the
meter will not function. Install the gears
as shown.
b. Position the gears perpendicular (90°)
to each other and install the rounded
bottom (RB) of the gear into the housing.
NOTE: Turn the gears to make sure that
NOTE:
NOTE:
stay engaged and rotate together once
installed. Reinstall the gears if they do
not stay engaged or rotate together.
10. Reinstall the flow meter. Reconnect the
heated hose and flow meter cable.
334946J