Replace Flow Meter; Replace Pressure Transducers - Graco Reactor 2 Repair Parts

Hydraulic proportioning systems
Hide thumbs Also See for Reactor 2:
Table of Contents

Advertisement

Repair
Replace Flow
Flow Meter
Meter
Replace
Replace
Flow
Meter
NOTE:
NOTE: For H-30, H-40, and H-50 Elite models
NOTE:
only.
1. Perform
Shutdown, page
2. Perform
Pressure Relief Procedure, page
3. Disconnect the flow meter cable.
4. Disconnect the hose. Remove the flow
meter.
5. Install the new flow meter and reconnect the
hose.
Figure 6 : Flow Meter
6. Connect the flow meter cable.
7. Enter the k-factor on System Screen 3 on
the ADM. Refer to System
operation manual.
62
50.
System 3 3 3 in your Reactor
System
Replace Pressure
Pressure Transducers
Replace
Replace
Pressure
1. Flush. See
2. See
Shutdown, page
3. Disconnect transducer cables (405) from #6
49.
and #7 connectors on the HCM.
4. Remove wire ties constraining transducer
cable and remove cable from cabinet.
5. Install o-ring (406) on new transducer (405).
6. Install transducer in manifold. Mark end
of cable with tape (red=transducer A,
blue=transducer B).
7. Route new cable into cabinet and thread
into bundle as before. Attach cable ties to
bundle as before.
8. Connect A side pressure transducer cable
to HCM port #6. Connect B side pressure
transducer cable to HCM port #7.
Transducers
Transducers
Flushing, page
51.
50.
334946J