Graco Reactor 2 Repair Parts page 25

Hydraulic proportioning systems
Hide thumbs Also See for Reactor 2:
Table of Contents

Advertisement

Error
Location
Error
Error
Location
Location
P4FB
ADM
P6AX
HCM
P6BX
HCM
P6FA
HCM
334946J
Type
Description
Type
Type
Description
Description
B Pump Inlet Leak
Pressure Sensor
Error A
Pressure Sensor
Error B
Pressure Sensor
Error Inlet A
Cause
Cause
Cause
Solution
Solution
Solution
Thermal
Condition the drum
expansion
material to the ambient
is occurring
temperature of the
between the
Reactor.
drum and Reactor
inlet
Damaged resin
Replace the resin pump
pump inlet ball
inlet ball and seat.
or seat
Loose/bad
Check to ensure the
connection
pressure transducer is
properly installed and
all wires are properly
connected.
Bad sensor
Check if the error
follows the transducer.
Disconnect transducer
cables from the HCM
(connectors 6 and
7). Reverse A and B
connections and check
if the errors follows. If
the error follows the
transducer, replace the
pressure transducer.
Loose/bad
Check to ensure the
connection
pressure transducer is
properly installed and
all wires are properly
connected.
Bad sensor
Check if the error
follows the transducer.
Disconnect transducer
cables from the HCM
(connectors 6 and
7). Reverse A and B
connections and check
if the errors follows. If
the error follows the
transducer, replace the
pressure transducer.
Inlet sensors not
If inlet sensors are not
installed
installed, inlet sensors
should be disabled on
the System Setup screen.
Loose/bad
Check to ensure inlet
connection
sensor is properly
installed and all wires are
properly connected.
Troubleshooting
25