Graco Reactor 2 Repair Parts page 33

Hydraulic proportioning systems
Hide thumbs Also See for Reactor 2:
Table of Contents

Advertisement

Error
Location
Error
Error
Location
Location
Heater A
T6DA
Heater B
T6DB
Hose
T6DH
334946J
Type
Description
Type
Type
Description
Description
Sensor Error A
Sensor Error B
Sensor Error Hose
Cause
Cause
Cause
Solution
Solution
Solution
Disconnected or
Check all wiring and
loose RTD cable
connections to the RTD.
or connection
Bad RTD
Switch the RTD with
another and see if the
error message follows
the RTD. Replace RTD if
the error follows the RTD.
Disconnected or
Check all wiring and
loose RTD cable
connections to the RTD.
or connection
Bad RTD
Switch the RTD with
another and see if the
error message follows
the RTD. Replace RTD if
the error follows the RTD.
Disconnected
Expose each hose RTD
or shorted RTD
connection to check and
cable in hose or
retighten any loose con-
bad FTS
nector. Measure hose
RTD cable and FTS conti-
nuity. See
Hose, page
RTD Test kit 24N365 for
measurement.
Disconnect the hose RTD
and use Hose Manual
Mode or Hose Resistance
Mode to continue the job
until repair can be com-
pleted. Hose Resistance
Mode requires a saved
calibration factor. Refer
to your proportioner op-
eration manual to enable
Hose Control Modes.
Troubleshooting
Repair Heated
65. Order
33

Advertisement

Table of Contents
loading

Table of Contents