Graco Reactor 2 Repair Parts page 35

Hydraulic proportioning systems
Hide thumbs Also See for Reactor 2:
Table of Contents

Advertisement

Error
Location
Error
Error
Location
Location
Heater B
T8DB
T8DH
Hose
V1IT
TCM
V2IT
TCM
V2MA
TCM
V2MB
TCM
334946J
Type
Description
Type
Type
Description
Description
No Temperature
Rise B
No Temperature
Rise Hose
Low Voltage CAN
Low Voltage CAN
Low Voltage A
Low Voltage B
Cause
Cause
Cause
Solution
Solution
Solution
Bad RTD or bad
Swap A and B heater
RTD placement
output cables and RTD
against heater
cables and see if issue
follows. If so, replace
RTD.
Bad heater
Confirm resistance of
element
heater. Heater resistance
should be 9-12 Ω for 10
kW systems, 6-8 Ω for
15 kW systems, 4–6 Ω for
20 kW systems. If out of
tolerance, replace heater
element.
Loose heater
Check for loose heater
wires
element wires.
Started spraying
Wait until operating
before heater
temperature has been
reached
reached before spraying
operating
or recirculating.
temperature
Started spraying
Wait until operating
before heater
temperature has been
reached
reached before spraying
operating
or recirculating.
temperature
Bad 24 VDC
Check voltage of power
power supply
supply. Voltage should
be 23-25 VDC. If out of
tolerance, replace power
supply.
Bad 24 VDC
Check voltage of power
power supply
supply. Voltage should
be 23-25 VDC. If out of
tolerance, replace power
supply.
Loose connection
Check wiring for loose
or tripped circuit
connection or tripped
breaker
circuit breaker.
Low incoming
Measure voltage at circuit
line voltage.
breaker and ensure
voltage is greater than
195 VAC.
Loose connection
Check wiring for loose
or tripped circuit
connection or tripped
breaker
circuit breaker.
Low incoming
Measure voltage at circuit
line voltage
breaker and ensure
voltage is greater than
195 VAC.
Troubleshooting