Graco Reactor 2 Repair Parts page 22

Hydraulic proportioning systems
Hide thumbs Also See for Reactor 2:
Table of Contents

Advertisement

Troubleshooting
Error
Location
Error
Error
Location
Location
L1BX
ADM
MMUX
USB
P0AX
HCM
P0BX
HCM
22
Type
Description
Type
Type
Description
Description
Low Chemical Level
B
Maintenance Due -
USB
Pressure Imbalance
A High
Pressure Imbalance
B High
Cause
Cause
Cause
Solution
Solution
Solution
Low material
Refill material and update
level
drum level on ADM
Maintenance screen.
Alarm can be disabled on
the System Setup screen.
USB logs have
Insert a USB drive into
reached a level
the ADM and download
where data loss
all logs.
will occur if
logs are not
downloaded.
Pressure
Ensure material flow is
difference
equally restricted on both
between A and
material lines.
B material is
greater than the
defined value
Pressure
Ensure that the pressure
imbalance is
imbalance value, on the
defined too low
System Setup screen, is at
an acceptable maximum
pressure to prevent
unnecessary alarms and
abort dispenses.
Out of material
Fill the tanks with
material.
Fluid leaking
Check if heater and
from heater inlet
PRESSURE RELIEF/SPRAY
rupture disk
valve are plugged. Clear.
Replace rupture disk. Do
not replace with a pipe
plug.
Feed system
Check feed pump and
defective
hoses for blockage.
Check that feed pumps
have correct air pressure.
Pressure
Ensure material flow is
difference
equally restricted on both
between A and
material lines.
B material is
greater than the
defined value
Pressure
Ensure that the pressure
imbalance is
imbalance value, on the
defined too low
System Setup screen, is at
an acceptable maximum
pressure to prevent
unnecessary alarms and
abort dispenses.
Fill the tanks with
Out of material
material.
334946J

Advertisement

Table of Contents
loading