Graco Reactor 2 Repair Parts page 34

Hydraulic proportioning systems
Hide thumbs Also See for Reactor 2:
Table of Contents

Advertisement

Troubleshooting
Error
Location
Error
Error
Location
Location
T6DT
TCM
Heater A
T8DA
34
Type
Description
Type
Type
Description
Description
Sensor Error TCM
No Temperature
Rise A
Cause
Cause
Cause
Solution
Solution
Solution
Shorted RTD
Expose each hose RTD
cable in hose
connection to check for
or FTS
exposed and shorted
RTD wires. Measure hose
RTD cable and FTS conti-
nuity. See
Hose, page
RTD Test kit 24N365 for
measurement.
Disconnect the hose RTD
and use Hose Manual
Mode or Hose Resistance
Mode to continue the job
until repair can be com-
pleted. Hose Resistance
Mode requires a saved
calibration factor. Refer
to your proportioner op-
eration manual to enable
Hose Control Modes.
Shorted A or B
If the error still occurs
Heater RTD
with the hose FTS
unplugged, one of
the heater RTDs is
bad. Unplug the A or
B RTD from the TCM. If
unplugging an RTD fixes
the T6DT error, replace
the RTD.
Bad RTD or bad
Swap A and B heater
RTD placement
output cables and RTD
against heater
cables and see if issue
follows. If so, replace
RTD.
Bad heater
Confirm resistance of
element
heater. Heater resistance
should be 9-12 Ω for 10
kW systems, 6-8 Ω for
15 kW systems, 4–6 Ω for
20 kW systems. If out of
tolerance, replace heater
element.
Loose heater
Check for loose heater
wires
element wires.
Started spraying
Wait until operating
before heater
temperature has been
reached
reached before spraying
operating
or recirculating.
temperature
Repair Heated
65. Order
334946J