Graco Reactor 2 Repair Parts page 24

Hydraulic proportioning systems
Hide thumbs Also See for Reactor 2:
Table of Contents

Advertisement

Troubleshooting
Error
Location
Error
Error
Location
Location
P4AX
HCM
P4BX
HCM
P4FA
ADM
24
Type
Description
Type
Type
Description
Description
High Pressure A
High Pressure B
A Pump Inlet Leak
Cause
Cause
Cause
Solution
Solution
Solution
System
Pressure in the hose and
pressurized
pumps will increase as
before allowing
the system heats up.
heat to reach
Turn on heat and allow
setpoint
all zones to reach the
temperature setpoint
before turning on the
pumps.
Bad pressure
Verify the ADM pressure
transducer
reading and the analog
gauges at the manifold.
Replace transducer if
they do not match.
H-XP2 or
Alarm level is lower for
H-XP3 system
H-30, H-40 and H-50
configured as
than for H-XP2 and
H-30, H-40, or
H-XP3.. Ensure dial on
H-50
HCM is set to position
"3" for H-XP2 or "4" for
H-XP3.
System
Pressure in the hose and
pressurized
pumps will increase as
before allowing
the system heats up.
heat to reach
Turn on heat and allow
setpoint
all zones to reach the
temperature setpoint
before turning on the
pumps.
Bad pressure
Verify the ADM pressure
transducer
reading and the analog
gauges at the manifold.
H-XP2 or
Alarm level is lower for
H-XP3 system
H-30, H-40 and H-50
configured as
than for H-XP2 and
H-30, H-40, or
H-XP3.. Ensure dial on
H-50
HCM is set to position
"3" for H-XP2 or "4" for
H-XP3.
Thermal
Condition the drum
expansion
material to the ambient
is occurring
temperature of the
between the
Reactor.
drum and Reactor
inlet
Damaged ISO
Replace the ISO pump
pump inlet ball
inlet ball and seat.
or seat
334946J